Siemens 840D 26010 - Axis QEC: invalid acceleration characteristic
Alarm 26010 indicates that one or more QEC (Quick Error Correction) acceleration characteristic parameters ($AA_QEC_ACCEL_1, $AA_QEC_ACCEL_2, or $AA_QEC_ACCEL_3) for the referenced axis contain invalid values outside their permissible ranges. The QEC acceleration characteristic divides the error correction into three quantization zones, and parameter values must fall within defined boundaries for proper NCK execution.
Siemens 840D 26010 - Axis QEC: invalid acceleration characteristic
Axis QEC: invalid acceleration characteristic
Siemens SINUMERIK alarm 26010: Axis QEC: invalid acceleration characteristic. This alarm indicates a fault or error condition on the SINUMERIK 840D control. Refer to the Siemens SINUMERIK alarm documentation for the complete description and remedy.
Root Cause Summary
Alarm 26010 indicates that one or more QEC (Quick Error Correction) acceleration characteristic parameters ($AA_QEC_ACCEL_1, $AA_QEC_ACCEL_2, or $AA_QEC_ACCEL_3) for the referenced axis contain invalid values outside their permissible ranges. The QEC acceleration characteristic divides the error correction into three quantization zones, and parameter values must fall within defined boundaries for proper NCK execution.
Safety
Causes and Fixes
Access Diagnostics > Parameters > Machine Data (MD) menu on the 840D control. Navigate to Axis-specific MD: $AA_QEC_ACCEL_1, $AA_QEC_ACCEL_2, and $AA_QEC_ACCEL_3 for the faulted axis (identify axis from %1 in alarm text).
Do not edit parameters while axis is enabled or NCK is running.
Verify each parameter value is within valid range (typically 1-100 for acceleration quantization percentage). Cross-reference against the machine builder's commissioning documentation or contact Siemens factory settings for your specific 840D model.
Default values should rarely be modified unless qualified commissioning engineer has documented compensation requirement.
If values are out of range, reset to defaults: $AA_QEC_ACCEL_1 = default value, $AA_QEC_ACCEL_2 = default value, $AA_QEC_ACCEL_3 = default value. Use 'Reset to Default' function if available in Siemens HMI, or manually enter documented factory defaults.
Save MD changes via 'Store' or 'Write' command. Perform warm restart (NCK stop/start cycle) and verify axis motion test without alarm recurrence.
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.