Siemens SINUMERIK codes
Siemens SINUMERIKOvertravel/LimitIntermediate30-120 minutes

26110

Siemens 840D 26110 - Independent drive stop/retract triggered

Independent drive stop/retract triggered

Siemens SINUMERIK alarm 26110: Independent drive stop/retract triggered. This alarm indicates a fault or error condition on the SINUMERIK 840D control. Refer to the Siemens SINUMERIK alarm documentation for the complete description and remedy.

Root Cause Summary

Alarm 26110 indicates that an independent extended stop or retract command was issued on the drive bus, causing the affected axis drive to enter a protective state and reject all subsequent NC travel commands. This is a drive-level safety intervention that requires hardware reset to recover communication and command authority.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check axis position against SoftLimit parameters: Navigate Diagnostics > Axes > [Axis] > Parameters and verify current actual position is within MD30200 (min) and MD30201 (max) ranges. If position violates limits, machine may have crashed or lost reference.

    Do NOT attempt to override limits without verifying mechanical integrity.

  2. 2

    Inspect hardware limit switches on the affected axis. Verify switch connectors at drive terminal block and check switch signal status in Diagnostics > Inputs > Digital Inputs. Look for intermittent or stuck limit signals.

    Ensure machine is in safe state before manual axis movement testing.

  3. 3

    Review following error data: Diagnostics > Axes > [Axis] > Actual Values. Compare actual position lag against MD32100 threshold. If lag is excessive, check servo parameter MD32110 (following error monitoring enable) and axis motor coupling for mechanical slip.

  4. 4

    Execute hardware reset: Power cycle the CNC control by switching main contactor OFF for 10 seconds, then ON. Monitor drive initialization on Diagnostics > Drives panel until all axes show READY state. Attempt controlled axis jog to verify recovery.

    Hardware reset will clear all non-persistent error logs. Document alarm details before reset.

Service Recommended confidence

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.