Siemens SINUMERIK Controller
Communication · Intermediate · 30-120 minutes
Siemens 26101 - Axis drive communication failure
Alarm 26101 indicates loss of communication between the NCK (numerical control kernel) and the drive control module via the DRIVE-CLiQ interface or servo amplifier connection. This prevents axis motion commands from reaching the drive and halts all controlled movements on the affected axis.
Siemens 26101 - Axis drive communication failure
Axis drive communication failure
For PROFIdrive only: The drive is not communicating Control reaction: Mode group not ready. The NC switches to follow-up mode. Channel not ready. NC Start disable in this channel. Axes of this channel must be re-referenced. Interface signals are set. Alarm display. NC Stop on alarm.
Root Cause Summary
Alarm 26101 indicates loss of communication between the NCK (numerical control kernel) and the drive control module via the DRIVE-CLiQ interface or servo amplifier connection. This prevents axis motion commands from reaching the drive and halts all controlled movements on the affected axis.
Safety
Causes and Fixes
Power down the machine and inspect the DRIVE-CLiQ connector on both the NCK interface module and drive %2. Check for bent pins, corrosion, or moisture ingress.
Ensure emergency stop is engaged and 24V DC supply is isolated before touching connectors.
Reseat the DRIVE-CLiQ cable firmly at both ends; listen for the connector click. Verify cable routing avoids high-voltage power lines and does not show visible damage, kinks, or pinch points.
If cable appears damaged, replace with a Siemens-certified DRIVE-CLiQ cable of correct length. Do not use aftermarket or third-party cables as they may not meet timing specifications.
Power up and monitor Diagnostics > Axis Status (NCK menu path: Service > Diagnostics > Axis %1) to confirm communication is re-established before resuming operation.
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.