Siemens 840D 10860 - Channel block feedrate not programmed

Channel block feedrate not programmed

Reason: In the displayed block, an interpolation type other than G00 (rapid traverse) is active. The F value has not been programmed. Path feed F is active, on change between linear and revolutional feedrate, F has not been programmed again. The modal feed for corner/chamfer (FRCM) is active, on cha

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Common Causes

  • Missing F (feedrate) value in a block where interpolation mode requires explicit feedrate specification
  • Switching between linear and revolutional feedrate without reprogramming F value
  • G01/G02/G03 or other non-rapid modes active without corresponding feedrate in current or previous blocks
  • Corner/chamfer modal feedrate (FRCM) active but F value not provided on mode change
  • Program assumes modal feedrate carry-over when feedrate type has changed

Troubleshooting Steps

  1. 1Review the NC program at the indicated block number and verify an F value is explicitly programmed before any G01, G02, G03, or other interpolation commands
  2. 2Check if feedrate mode has switched between linear (mm/min) and revolutional (rev/min) and ensure F is reprogrammed for the new mode
  3. 3Confirm that if corner/chamfer modal feedrate (FRCM) is active, the F value is included when transitioning between feedrate types
  4. 4Verify no G00 rapid traverse is mistakenly replaced with G01 or G02 without an accompanying F command
  5. 5Add or correct the missing F value in the program block, then reload and test the program from a safe starting position