Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate30-60 minutes

10881

Siemens 10881 - Block overflow of local block buffer in the case of chamfers or radii

Block overflow of local block buffer in the case of chamfers or radii

Between 2 blocks containing the contour elements and to be joined with a chamfer or a radius (CHF, RND), so many dummy blocks have been programmed without contour information that the internal buffer is too small Control reaction: Correction block is reorganized. Local alarm reaction. Interface signals are set. Alarm display.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Common Causes

  • Between 2 blocks containing the contour elements and to be joined with a chamfer or a radius (CHF, RND), so many dummy blocks have been programmed without contour information that the internal buffer is too small

Troubleshooting Steps

  1. 1Modify part program such that the number of dummy blocks is reduced.
  2. 2Clear alarm with NC START or RESET key and continue the program

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?