Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate30-120 minutes

100303

Siemens 840D 100303 - Paging not possible

Paging not possible

Siemens SINUMERIK alarm 100303: Paging not possible. This alarm indicates an error condition in the NC program or control configuration that must be resolved before the operation can continue.

Root Cause Summary

SIEMENS alarm 100303 occurs when attempting to navigate through HMI pages for axes, drives, or channels that exceed the configured system limits. This typically happens when using the paging functions in commissioning or diagnostic screens where the system tries to access non-existent hardware configurations.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check Axis Configuration

    Navigate to HMI → Commissioning → Axis → Machine Data and verify MD30100 (Number of axes) matches your actual hardware setup.

    Compare MD30100 with the physical axis count on your machine

  2. 2

    Verify Drive Configuration

    Check MD36000 (Drive type) for each configured axis and ensure all required drives are properly defined in the machine data.

    Incorrect drive configuration can cause servo faults

  3. 3

    Validate Channel Settings

    Review MD20070 (Number of channels) in HMI → Commissioning → Channel → General to ensure it matches your NC program requirements.

  4. 4

    Reset and Recompile

    After corrections, perform a complete reset via HMI → Commissioning → System → Reset → Complete reset to rebuild the configuration.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Software update required
  • ·Hardware configuration changes needed
  • ·Persistent alarm after all troubleshooting steps

Prevention

  • Always complete full commissioning wizard during initial setup
  • Regularly backup machine data before configuration changes
  • Keep HMI and NCK software versions synchronized

Common Mistakes

  • Attempting to access non-configured axes through HMI navigation
  • Incomplete commissioning leaving undefined parameters
  • Mixing different software versions without compatibility check

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.