Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate30-120 minutes

100135

Siemens 840D 100135 - Value too large for display field ->input ignored

Value too large for display field ->input ignored

Siemens SINUMERIK operator message 100135: Value too large for display field ->input ignored. This is an informational message from the SINUMERIK control indicating a system status or operation result that may require operator action.

Root Cause Summary

SIEMENS alarm 100135 occurs when a numerical value entered into a SINUMERIK display field exceeds the allowable range or format limits for that specific parameter. This typically happens during manual data input in machine data, setting data, or tool offset screens where the entered value is outside the defined min/max boundaries or contains invalid characters.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Identify the Parameter Field

    Note which machine data parameter was being modified when alarm occurred. Check HMI display for the active MD number and field name.

    The alarm typically appears immediately after pressing ENTER or INPUT key

  2. 2

    Verify Parameter Limits

    Access SINUMERIK documentation or use HMI Help function to check valid range for the specific MD parameter. Navigate to Diagnostics > Help > Machine Data.

    Never guess parameter ranges - always verify against official documentation

  3. 3

    Enter Corrected Value

    Input a value within the documented range limits. Use proper decimal notation and ensure no leading/trailing spaces or invalid characters.

    Use scientific notation (e.g., 1.5E-3) for very small values if supported by the parameter

  4. 4

    Validate and Reset

    Press INPUT key to confirm entry. If accepted, press RESET key to clear alarm. Cycle power if parameter requires restart to take effect.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Parameter limits need modification requiring safety assessment
  • ·Repeated alarms after correct value entry indicate HMI hardware issues
  • ·Machine data corruption suspected

Prevention

  • Always verify parameter ranges before data entry
  • Use copy/paste carefully to avoid format errors
  • Implement input validation procedures for operators
  • Regular backup of machine and setting data

Common Mistakes

  • Entering values without checking parameter documentation
  • Using wrong decimal separator (comma vs period)
  • Copying values from different SINUMERIK versions with different limits
  • Ignoring data type requirements for parameters

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.