Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate30-120 minutes

100144

Siemens 840D 100144 - Error on saving the file

Error on saving the file

Siemens SINUMERIK alarm 100144: Error on saving the file. This alarm indicates an error condition in the NC program or control configuration that must be resolved before the operation can continue.

Root Cause Summary

SIEMENS alarm 100144 'Error on saving the file' occurs when the SINUMERIK system cannot write data to storage locations, typically during parameter backup, program storage, or configuration saves. This servo-category alarm indicates file system issues affecting servo parameter persistence or program file operations.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check CF card write protection

    Navigate to HMI > Diagnostics > Hardware > Storage and verify CF card status. Check physical write-protect switch on CF card.

    Power down NCK before removing CF card to prevent data corruption

  2. 2

    Verify CF card capacity and health

    In HMI > Service > Memory, check available space. Verify CF card health using SINUMERIK diagnostic functions.

    SINUMERIK requires minimum 15% free space on CF card for reliable operation

  3. 3

    Replace CF card if necessary

    If CF card shows errors or insufficient space, replace with SIEMENS-approved CF card and restore from backup using NCK backup/restore function.

DIY Feasiblehigh confidence

Call a technician if:

  • ·CF card replacement required
  • ·NCK file system repair fails
  • ·Network infrastructure issues

Prevention

  • Regular CF card health monitoring
  • Maintain adequate free space on storage devices
  • Perform regular NCK data backups
  • Use appropriate user access levels

Common Mistakes

  • Attempting saves during active machining
  • Ignoring CF card write protection
  • Using insufficient user permissions
  • Not checking available storage space

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.