axismd.ai
Siemens SINUMERIK Controller
Program/G-code · Intermediate · 30-120 minutes
Siemens 840D 100143 - Error on reading the file!
SIEMENS alarm 100143 'Error on reading the file!' occurs when the SINUMERIK control cannot access or properly read configuration files, typically during system startup or parameter loading. This servo-category alarm indicates file system corruption, incorrect file permissions, or hardware issues with the CF card or hard drive.
Siemens 840D 100143 - Error on reading the file!
Error on reading the file!
Siemens SINUMERIK alarm 100143: Error on reading the file!. This alarm indicates an error condition in the NC program or control configuration that must be resolved before the operation can continue.
Root Cause Summary
SIEMENS alarm 100143 'Error on reading the file!' occurs when the SINUMERIK control cannot access or properly read configuration files, typically during system startup or parameter loading. This servo-category alarm indicates file system corruption, incorrect file permissions, or hardware issues with the CF card or hard drive.
Safety
Causes and Fixes
Check CF Card Status
Navigate to HMI → Diagnostics → Hardware → Storage and verify CF card health status and available space.
Look for error counters or bad sector reports in the storage diagnostics
Perform File System Check
Access Service Mode and run CHKDSK utility on the CF card to identify and repair file system errors.
Always backup critical data before running file system repairs
Replace CF Card if Necessary
If corruption persists, replace the CF card and restore from backup using Siemens backup/restore utility.
Use only Siemens-approved CF cards to ensure compatibility
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.