Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate30-120 minutes

100154

Siemens 840D 100154 - USB device no longer available, of Extcall no longer

USB device no longer available, of Extcall no longer

Siemens SINUMERIK message 100154: USB device no longer available, of Extcall no longer. This is an operator information message from the SINUMERIK control. Note the complete message text as it may contain important parameter values.

Root Cause Summary

SIEMENS alarm 100154 occurs when a USB device that was previously connected and being used by an external call (Extcall) function becomes unavailable during operation. This typically happens when USB communication is interrupted while the SINUMERIK system is executing external programs or accessing USB-stored data.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check USB physical connection

    Verify USB device is properly seated in the USB port on the NCU or HMI unit. Check for loose connections or damaged USB connectors.

    Ensure machine is in a safe state before checking connections

  2. 2

    Verify USB device status

    Navigate to HMI > Diagnostics > Hardware > USB to check if the USB device is recognized by the system.

    USB devices should show as 'Connected' status in the hardware diagnostics

  3. 3

    Reset Extcall function

    Clear the alarm and restart the Extcall function from the part program or through the HMI interface to re-establish USB communication.

DIY Feasiblehigh confidence

Call a technician if:

  • ·USB hardware replacement needed
  • ·NCU/HMI hardware diagnostics required
  • ·System software corruption suspected

Prevention

  • Use high-quality USB devices with proper power ratings
  • Implement proper Extcall timeout values
  • Regularly check USB connections during maintenance
  • Avoid removing USB devices during active operations

Common Mistakes

  • Removing USB device while Extcall is active
  • Using low-quality or incompatible USB devices
  • Not setting appropriate timeout values for USB operations
  • Ignoring USB power supply requirements

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.