Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate30-120 minutes

100170

Siemens 840D 100170 - File is binary: editing and paging not possible!

File is binary: editing and paging not possible!

Siemens SINUMERIK alarm 100170: File is binary: editing and paging not possible!. This alarm indicates an error condition in the NC program or control configuration that must be resolved before the operation can continue.

Root Cause Summary

SIEMENS alarm 100170 occurs when attempting to edit or view a binary file through the SINUMERIK HMI text editor or file browser. The system cannot display binary content in text format, preventing editing operations on compiled programs, system files, or corrupted NC programs.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access Program Manager

    Navigate to HMI → Program Manager → NC Programs to view file list and check file extensions.

    Look for files with .SPF or .MPF extensions that show unusual file sizes

  2. 2

    Check file properties

    Right-click on the problematic file and select Properties to verify if it's marked as binary or compiled.

    Do not attempt to force-edit binary files as this can corrupt the program

  3. 3

    Access source code

    Look for the original source file with .SPF.SRC or .MPF.SRC extension, or restore from backup if available.

    Enable 'Show source files' in Program Manager settings to display .SRC files

  4. 4

    Recompile if necessary

    If source exists, delete binary version and let SINUMERIK recompile from source during next program call.

DIY Feasiblehigh confidence

Call a technician if:

  • ·System files are corrupted
  • ·File system consistency check fails
  • ·HMI software update required

Prevention

  • Always use ASCII mode for NC program transfers
  • Maintain regular program backups through Archive function
  • Monitor HMI memory usage regularly
  • Use proper file extensions (.SPF, .MPF) for NC programs

Common Mistakes

  • Trying to force-edit binary files
  • Using binary transfer mode for text programs
  • Editing system files directly instead of using configuration tools
  • Not checking file properties before editing attempts

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.