Siemens 840D 100156 - USB device no longer available, was aborted.

USB device no longer available, was aborted.

Siemens SINUMERIK alarm 100156: USB device no longer available, was aborted. This alarm indicates a required configuration element, parameter, or program component is missing or has not been set up.

Root Cause Summary

SIEMENS alarm 100156 occurs when a USB storage device becomes unavailable during an active file transfer operation on the SINUMERIK control. This typically happens during NC program transfers, backup operations, or parameter file copying when the USB connection is interrupted or the device fails.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check USB connection status

    Navigate to HMI → Services → USB and verify if the USB device is still recognized in the device list.

    Use only industrial-grade USB devices rated for vibration environments

  2. 2

    Inspect USB port and connector

    Physically examine the USB port on the HMI/NCU and the connector on the storage device for damage, debris, or loose connections.

    Power down the system before cleaning USB ports to prevent ESD damage

  3. 3

    Restart transfer operation

    Reinsert the USB device, wait for recognition, then restart the file transfer from HMI → Program Manager → External.

    Always use 'Safely Remove Hardware' function before disconnecting USB devices

DIY Feasiblehigh confidence

Call a technician if:

  • ·Multiple USB devices fail on same system
  • ·System resources consistently show high usage
  • ·Network infrastructure changes required

Prevention

  • Use industrial-grade USB devices rated for manufacturing environments
  • Implement regular USB device health checks and replacement schedules
  • Always use 'Safely Remove Hardware' before disconnecting USB devices
  • Maintain dedicated USB devices for each machine to avoid cross-contamination

Common Mistakes

  • Removing USB devices during active transfers
  • Using consumer-grade USB devices in industrial environments
  • Ignoring file system errors on USB devices
  • Not checking available system resources before large transfers