Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate30-120 minutes

100157

Siemens 840D 100157 - USB device no longer available.

USB device no longer available.

Siemens SINUMERIK alarm 100157: USB device no longer available. This alarm indicates a required configuration element, parameter, or program component is missing or has not been set up.

Root Cause Summary

SIEMENS alarm 100157 indicates a USB device that was previously connected and recognized by the SINUMERIK system has become unavailable or disconnected. This typically occurs when USB storage devices, dongles, or other peripherals lose connection during operation or fail to respond to system queries.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check USB physical connections

    Inspect all USB connections on the NCU and HMI. Check USB ports on the operator panel and any connected devices for loose connections or physical damage.

    Power down the system before disconnecting/reconnecting USB devices to prevent data corruption.

  2. 2

    Test USB cable integrity

    Replace the USB cable with a known good cable. Ensure cable meets USB 2.0 specifications and is not longer than 5 meters for reliable communication.

    Use shielded USB cables in industrial environments to prevent EMI interference.

  3. 3

    Verify USB port functionality

    Test the USB port with a different known working device. Navigate to HMI > Diagnostics > Hardware to check USB port status in the system diagnostics.

    USB ports on the NCU are more reliable than those on the operator panel for critical applications.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Multiple USB ports failing simultaneously
  • ·Power supply voltage readings outside specification
  • ·Persistent issues after driver reinstallation

Prevention

  • Use industrial-grade USB devices rated for CNC environments
  • Implement regular USB device rotation to prevent wear
  • Maintain proper cable management away from EMI sources
  • Perform monthly USB connection inspections

Common Mistakes

  • Hot-plugging USB devices without proper ejection
  • Using consumer-grade USB devices in industrial environment
  • Ignoring EMI considerations in USB cable routing
  • Exceeding USB port power limitations with multiple devices

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.