Siemens 840D 100134 - Sign change - position of cursor changed!

Sign change - position of cursor changed!

Siemens SINUMERIK operator message 100134: Sign change - position of cursor changed!. This is an informational message from the SINUMERIK control indicating a system status or operation result that may require operator action.

Root Cause Summary

SIEMENS alarm 100134 occurs when the sign of the position feedback changes unexpectedly during cursor positioning or reference point approach, indicating encoder signal issues or mechanical problems. This alarm typically fires when the control detects inconsistent position data that suggests the axis has moved in the opposite direction than commanded.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check encoder cable integrity

    Inspect encoder cables for physical damage, proper shielding, and secure connections at both motor and drive ends.

    Ensure machine is in safe state before accessing electrical connections

  2. 2

    Verify encoder supply voltage

    Check encoder supply voltage at terminal X521 on the drive module, should be within ±5% of nominal value (typically 5V or 15V).

    Use oscilloscope to check for voltage ripple or noise on encoder supply

  3. 3

    Test encoder signal quality

    Monitor encoder signals A, B, and Z channels using SINUMERIK diagnostics under Service > Drive > Encoder signals display.

    Look for signal amplitude variations or missing pulses during slow axis movement

  4. 4

    Check EMC compliance

    Verify proper cable routing separation between encoder cables and power cables, ensure encoder cable shielding is properly grounded.

    Minimum 200mm separation between encoder and motor power cables

DIY Feasiblemedium confidence

Call a technician if:

  • ·Drive module replacement required
  • ·Encoder replacement needed
  • ·Mechanical coupling repair required

Prevention

  • Regular encoder cable inspection
  • Proper EMC installation practices
  • Periodic mechanical backlash measurement
  • Maintain proper drive cooling

Common Mistakes

  • Ignoring encoder cable shielding requirements
  • Incorrect machine data parameter entry
  • Mixing encoder types without parameter updates
  • Inadequate mechanical coupling maintenance

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.