Servo/Axis · Advanced · 30 - 90 min
Siemens 25201 - Axis drive fault
SIEMENS alarm 25201 TRANSMIT Error indicates a communication failure in the SINUMERIK data transmission chain, typically between the NCK and HMI or during program/parameter transfer operations. This alarm is triggered when the system detects corrupted data packets, timeout conditions, or hardware communication interface failures.
Siemens 25201 - Axis drive fault
Axis drive fault
For PROFIdrive: The drive signals a serious fault which prevents the drive from being ready. The exact cause of the fault can be found by evaluating the additionally output drive alarms (It may be necessary to activate these diagnostic alarms by parameterizing the MDs DRIVE_FUNCTION_MASK, PROFIBUS_ALARM_ACCESS etc): Alarms 380500 and 380501 (or the corresponding alarm numbers implemented on the HMI side). The alarm can be reprogrammed in the MD11412 $MN_ALARM_REACTION_CHAN_NOREADY (channel not ready) Control reaction: Mode group not ready. The NC switches to follow-up mode. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm. Channel not ready.
Root Cause Summary
SIEMENS alarm 25201 TRANSMIT Error indicates a communication failure in the SINUMERIK data transmission chain, typically between the NCK and HMI or during program/parameter transfer operations. This alarm is triggered when the system detects corrupted data packets, timeout conditions, or hardware communication interface failures.
Safety
Causes and Fixes
Check Ethernet Cable Connections
Verify X120 and X130 Ethernet connections are secure. Check cable integrity with multimeter for continuity on pins 1,2,3,6.
Power down system before disconnecting Ethernet cables to prevent data corruption.
Verify Network Configuration
Access Commissioning → Network → Ethernet settings. Verify IP addresses match MD11210 (NCK_IP_ADDRESS) and MD11211 (HMI_IP_ADDRESS).
Default NCK IP is typically 192.168.214.1, HMI is 192.168.214.10
Test Communication with PING
Use HMI diagnostics menu → Service → Network diagnostics to ping NCK. Response time should be <10ms.
Packet loss >5% indicates hardware interface degradation
Replace Ethernet Interface Module
If ping fails consistently, replace the Ethernet interface card (typically 6FC5357-0BB35-0AA0 for NCU).
Ensure exact part number match and proper ESD handling procedures
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?