Okuma OSP codes
Okuma OSPServo/AxisIntermediate

1165

Okuma OSP Alarm A 1165 - MCS Encoder initialization failure

MCS Encoder initialization failure

The control could not complete the startup handshake with a motor encoder over the encoder link. The affected axis (or spindle, if no axis is named) cannot be used until the encoder initializes, which usually points to the encoder itself, its link cable, or the inverter control board.

Common Causes

  • Faulty motor encoder on the named axis or spindle
  • Damaged or loose encoder link cable or connector
  • Failed inverter unit control board
  • Encoder parameter mismatch (incomplete parameter transfer or multi-rotation range mismatch)

Troubleshooting Steps

  1. 1Read the code number shown with the alarm: code XX=0 = Failure during link reset; code XX=1 = Failure during network address setting; code XX=2 = Failure requesting basic communication information; code XX=3 = Failure changing communication version; code XX=4 = Failure acquiring device information; code XX=5 = Failure during parameter change; code XX=6 = Failure at AT (auto) mode start; code YY=0 = Communication error; ZZZZ shows encoder link error status C2ERR
  2. 2Read the code on screen: XX shows which link sequence step failed (e.g. 2 = basic communication info request, 5 = parameter change), YY shows the error type, and ZZZZ gives detail.
  3. 3If YY=6 (parameter error), check ZZZZ: 1 means not all required parameters arrived, 2 means communication basic info is incompatible, 3 means the multi-rotation detection range does not match — re-check the encoder-related setup for that axis.
  4. 4If YY=0 (communication error), power down and lock out, then inspect and reseat the encoder link cable connectors at both the motor encoder and the inverter unit; look for bent pins, coolant ingress, or chafed cable along the axis run.
  5. 5Swap or substitute the encoder link cable with a known-good one if available; a broken link cable is the most common field cause.
  6. 6If the cable and connectors are good, the motor encoder itself is suspect — replace the encoder on the named axis/spindle.
  7. 7Only after cable and encoder are eliminated should the inverter unit control board be replaced; if the alarm returns, record the full XXYYZZZZ code and contact Okuma service.

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.