KUKA Robot KRC0151 - Undervoltage <kps number> while charging

Undervoltage <kps number> while charging

This alarm indicates that the KPS (KUKA Power Supply) unit is detecting an undervoltage condition during the charging phase of the robot's backup battery system. The voltage has fallen below the minimum threshold required for safe charging operations, preventing proper energy storage in the system's power reserve.

Common Causes

  • Insufficient input AC mains voltage supply to the KPS unit
  • Faulty or degraded main power supply circuit breaker or contactor
  • Damaged power cables or loose electrical connections at the KPS input terminals
  • Defective charging circuit within the KPS module or internal voltage regulation failure
  • Excessive load demand during charging cycle exceeding available power capacity

Troubleshooting Steps

  1. 1Verify that the main AC mains voltage supply meets specification (typically 3-phase 400V ±10%) using a multimeter at the KPS input terminals
  2. 2Inspect all power supply cables and connectors for visible damage, corrosion, or loose contacts and reseat connections firmly
  3. 3Check that the main circuit breaker and any isolation switches are fully engaged and not tripped
  4. 4Reduce peripheral system loads and restart the charging cycle to determine if the issue is load-related
  5. 5If voltage is confirmed adequate, reset the KPS module by cycling the main power switch off for 30 seconds then back on
  6. 6If the alarm persists, the KPS unit likely requires replacement or service; contact KUKA support or an authorized service technician