Heidenhain codes
HeidenhainToolIntermediate30-120 minutes

600-0267

HEIDENHAIN 600-0267 - Tool with the defined diameter was not found. Select tool with a smaller diameter.

Tool with the defined diameter was not found. Select tool with a smaller diameter.

A tool-related error occurred during automatic operation. The tool may have incorrect parameters or may not be suitable for the operation.

Root Cause Summary

HEIDENHAIN alarm 600-0267 occurs when the TNC control cannot locate a tool with the specified diameter in the tool table or turret, or when the available tool diameter is too large for the programmed operation. This typically happens during automatic tool selection or when executing cycles that require specific tool geometries.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access tool table

    Press MOD key, select 'Tool table' to open TOOL.T file and verify tool entries.

    Use F3 search function to quickly locate tools by diameter

  2. 2

    Check tool diameter entry

    Verify column R (radius) or DL (length) contains correct tool diameter values for required tool number.

    Ensure R value is radius, not diameter - TNC uses radius internally

  3. 3

    Add missing tool entry

    Insert new tool line with correct T number, R value, and tool type (column TYPE) matching program requirements.

  4. 4

    Reload tool table

    Press END key to save changes and reload tool table into TNC memory.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Tool detection sensors malfunction
  • ·Turret indexing problems
  • ·Persistent alarm after tool table corrections

Prevention

  • Maintain accurate tool table with current tool inventory
  • Use tool management software for automatic updates
  • Implement tool presetting procedures
  • Regular verification of tool table against physical turret contents

Common Mistakes

  • Confusing radius vs diameter values in tool table
  • Not reloading tool table after changes
  • Assuming tool presence without physical verification
  • Using outdated backup tool tables

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.