Heidenhain 600-02E7 - Multi-cut tools are not supported and are therefore rejected.
The Heidenhain 600-02E7 alarm typically occurs when the CNC system rejects multi-cut tools due to unsupported automatic tool selection features. The most likely fix involves manually configuring tool parameters or updating the control software to handle such tools if possible. In many cases, adjusting the tool table or program settings resolves the issue.
Heidenhain 600-02E7 - Multi-cut tools are not supported and are therefore rejected.
Multi-cut tools are not supported and are therefore rejected.
Heidenhain TNC error 600-02E7: Multi-cut tools are not supported and are therefore rejected. This alarm indicates a fault or error condition on the Heidenhain TNC control that requires investigation. Refer to the Heidenhain NC error message documentation for the specific cause and remedy for this alarm code.
Root Cause Summary
The Heidenhain 600-02E7 alarm typically occurs when the CNC system rejects multi-cut tools due to unsupported automatic tool selection features. The most likely fix involves manually configuring tool parameters or updating the control software to handle such tools if possible. In many cases, adjusting the tool table or program settings resolves the issue.
Safety
Causes and Fixes
Check Software Version
Access the control panel and navigate to the system information menu to note the current software version of the Heidenhain control system.
Compare the version number against the latest release notes available on the Heidenhain website for compatibility details.
Ensure the machine is powered down before accessing internal menus if required by your model.
Verify Compatibility
Cross-reference the software version with the Heidenhain documentation or support portal to confirm if multi-cut tools are supported in this version.
Contact Heidenhain support for a quick compatibility check if documentation is unclear.
N/A
Update Software if Necessary
If the current version does not support multi-cut tools, download and install the latest compatible software update from the Heidenhain website, following their update procedure.
Backup all machine parameters and programs before updating to avoid data loss.
Ensure a qualified technician performs the update to prevent system errors.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.