HEIDENHAIN 600-02ED - No tool found. Please check tappet length.

No tool found. Please check tappet length.

No suitable tool was found for the automatic workpiece generation. This may be due to incorrect tool geometry parameters or unsuitable tool types.

Root Cause Summary

HEIDENHAIN alarm 600-02ED occurs when the Automatic Workpiece Gaging (AWG) optimization routine cannot find any suitable tools in the tool table, typically due to incorrect tappet length configuration or tool geometry parameters. The AWG system evaluates all available tools and rejects them as unsuitable for the current workpiece setup.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access Tool Table

    Press TOOL CALL key, then select 'Tool table' from the TNC menu to access tool management.

    Use F4 key to toggle between different tool table views for easier parameter verification

  2. 2

    Verify Tappet Length Parameter

    Check column 'L3' (tappet length) for the measuring probe tool. Compare with physical probe assembly dimensions.

    Incorrect tappet length can cause probe collision during AWG cycles

  3. 3

    Measure and Update Tappet Length

    Physically measure the probe tappet length and update the L3 parameter in the tool table. Save changes with ENT key.

    Use a height gauge or coordinate measuring machine for precise tappet length measurement

  4. 4

    Reset AWG Optimization

    Navigate to 'Setup' > 'AWG Settings' and select 'Reset optimization' to clear previous unsuitable tool flags.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Machine parameter modifications required
  • ·Kinematic calibration needed
  • ·Hardware probe replacement necessary

Prevention

  • Regularly validate tool table geometry parameters
  • Maintain accurate tappet length measurements
  • Document AWG setup parameters for different workpiece types
  • Perform periodic AWG system calibration

Common Mistakes

  • Confusing tappet length with total tool length
  • Not updating tool table after probe changes
  • Setting workpiece dimensions larger than machine envelope
  • Forgetting to reset AWG optimization after tool table changes