axismd.ai
Heidenhain Controller
Tool · Intermediate · 30-120 minutes
HEIDENHAIN 600-0302 - No tool and turret data defined for entered slide number.
Alarm 600-0302 occurs when the TNC control cannot find valid tool and turret configuration data for the specified slide number in a multi-spindle or multi-turret machine setup. This typically happens when tool table entries are missing, turret parameters are undefined, or there's a mismatch between the programmed slide number and the configured machine geometry.
HEIDENHAIN 600-0302 - No tool and turret data defined for entered slide number.
No tool and turret data defined for entered slide number.
A tool-related error occurred during automatic operation. The tool may have incorrect parameters or may not be suitable for the operation.
Root Cause Summary
Alarm 600-0302 occurs when the TNC control cannot find valid tool and turret configuration data for the specified slide number in a multi-spindle or multi-turret machine setup. This typically happens when tool table entries are missing, turret parameters are undefined, or there's a mismatch between the programmed slide number and the configured machine geometry.
Safety
Causes and Fixes
Access Tool Table
Press MOD key, select 'Tables' and open TOOL.T table to verify tool entries for the slide number referenced in alarm.
Use filter function in tool table to display only tools assigned to specific slide numbers
Verify Slide Assignment Column
Check column 'KINEMATIC' or 'SLIDE' in tool table and ensure tools have proper slide number assignments matching your machine configuration.
Incorrect slide assignments can cause collision during tool changes
Add Missing Tool Entries
Create new tool entries with correct slide number assignment, tool length, and radius compensation values for the referenced slide.
Copy existing tool entries and modify slide assignment to maintain consistent tool data structure
Save and Reset Control
Save tool table changes and perform control reset (END + 1) to reload tool management data into active memory.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.