Heidenhain codes
HeidenhainToolIntermediate30-120 minutes

600-030F

HEIDENHAIN 600-030F - Tool has no cam or location number.

Tool has no cam or location number.

A tool-related error occurred during automatic operation. The tool may have incorrect parameters or may not be suitable for the operation.

Root Cause Summary

Alarm 600-030F occurs when a tool in the tool table lacks proper cam number or location number assignment in the tool management database. This typically happens during tool setup or when tool data becomes corrupted in the TNC's tool management system.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access tool table

    Press MOD key, select 'Tool table' from the TNC menu to open TOOL.T table.

    Use Ctrl+F to quickly search for the specific tool number mentioned in the alarm

  2. 2

    Check CAM column

    Locate the tool number from the alarm and verify the CAM column entry. Look for empty or invalid cam number.

    Do not modify cam numbers while spindle is running

  3. 3

    Assign correct cam number

    Enter the appropriate cam number based on your tool changer configuration. Consult machine documentation for valid cam number range.

    Cam numbers typically range from 1-99 depending on your ATC configuration

  4. 4

    Save and test

    Press END key to save changes, then test tool call with M6 T[tool number] to verify alarm clears.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Machine parameter access restricted
  • ·Database corruption persists after restore
  • ·Tool changer hardware malfunction suspected

Prevention

  • Always complete full tool setup procedure when adding new tools
  • Regularly backup tool management database
  • Verify tool table entries after any system updates

Common Mistakes

  • Skipping cam number assignment during tool setup
  • Using invalid cam numbers outside configured range
  • Not saving tool table changes properly

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.