axismd.ai
Heidenhain Controller
Tool · Intermediate · 30-120 minutes
HEIDENHAIN 600-030E - No tool was found that also fits in the tool mount location.
HEIDENHAIN alarm 600-030E occurs when the TNC control cannot find a tool with a mount type that matches the available tool carrier mount location. This typically happens during automatic tool selection when the tool table mount type definitions don't align with the actual spindle or tool changer configuration.
HEIDENHAIN 600-030E - No tool was found that also fits in the tool mount location.
No tool was found that also fits in the tool mount location.
A tool-related error occurred during automatic operation. The tool may have incorrect parameters or may not be suitable for the operation.
Root Cause Summary
HEIDENHAIN alarm 600-030E occurs when the TNC control cannot find a tool with a mount type that matches the available tool carrier mount location. This typically happens during automatic tool selection when the tool table mount type definitions don't align with the actual spindle or tool changer configuration.
Safety
Causes and Fixes
Access Tool Table
Press MOD key, select 'Tool table' from the TNC menu to open TOOL.T table.
Use Ctrl+F to quickly search for specific tool numbers in large tool tables.
Check Mount Type Column
Verify the MT (Mount Type) column entry for the tool referenced in %1 parameter matches available mount types (typically 0=SK40, 1=HSK63, 2=HSK100, etc.).
Never modify mount types without confirming physical tool holder compatibility.
Cross-Reference Tool Carrier Table
Open Tool Carrier table (TOOLCARR.TCH) and verify matching mount type entries exist for the spindle position.
Use machine parameter 7160.x to define standard mount type assignments if using automatic tool management.
Correct Mount Type Entry
Update the tool table MT column to match an available tool carrier mount type, or install appropriate tool carrier.
Ensure physical tool holder actually matches the mount type being programmed.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.