Heidenhain codes
HeidenhainToolIntermediate30-120 minutes

600-0379

HEIDENHAIN 600-0379 - Tool not contained in data base. (Tool number)!

Tool not contained in data base. (Tool number)!

A tool-related error occurred during automatic operation. The tool may have incorrect parameters or may not be suitable for the operation.

Root Cause Summary

Alarm 600-0379 occurs when the TNC control detects a tool in the spindle or turret that is not defined in the tool table (TOOL.T). This typically happens when tools are manually inserted without proper tool data entry or when tool numbers don't match between the physical tool and the control's database.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access Tool Table

    Press MOD key, select 'Tables' then 'Tool table' or directly access via TOOL CALL menu to open TOOL.T table.

    Use Ctrl+F to quickly search for specific tool numbers in large tool tables

  2. 2

    Verify Tool Number

    Check the tool number displayed in the alarm message (%2 parameter) and confirm if this tool number exists in the TOOL.T table.

    Ensure spindle is stopped before checking tool numbers

  3. 3

    Create Tool Entry

    If tool is missing, create new entry in TOOL.T with correct tool number, length (L), radius (R), and other required parameters like tool type and cutting data.

    Copy similar tool entries and modify parameters to save time

  4. 4

    Validate Tool Data

    Execute TOOL CALL with the newly created tool number to verify the entry is properly recognized by the control.

    Always perform dry run after adding new tool entries

DIY Feasiblehigh confidence

Call a technician if:

  • ·File system corruption beyond basic recovery
  • ·Network/DNC communication issues requiring IT support
  • ·Hardware tool identification system failures

Prevention

  • Always update tool table when physically changing tools
  • Implement regular tool table backups
  • Use consistent tool numbering system
  • Train operators on proper tool entry procedures

Common Mistakes

  • Inserting tools without updating tool table
  • Using duplicate tool numbers
  • Incorrect tool parameter entry
  • Ignoring tool management system protocols

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.