Heidenhain codes
HeidenhainToolIntermediate30-120 minutes

600-030B

HEIDENHAIN 600-030B - Selection parameter for tool selection mode not set!

Selection parameter for tool selection mode not set!

A tool-related error occurred during automatic operation. The tool may have incorrect parameters or may not be suitable for the operation.

Root Cause Summary

HEIDENHAIN alarm 600-030B occurs when the tool selection mode parameter is not properly configured in the spindle configuration. This typically happens when MP7160 (tool selection mode) is undefined or set incorrectly, preventing the TNC from determining how to handle tool changes.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access Machine Parameters

    Press MOD key, select 'Machine parameters' from the TNC menu, navigate to spindle parameters section.

    Ensure machine is in a safe state before accessing machine parameters.

  2. 2

    Check MP7160 Value

    Locate MP7160 (Tool selection mode) and verify it has a valid value (typically 1-4 depending on tool changer type).

    Common values: 1=random tool changer, 2=chain magazine, 3=disk magazine, 4=manual tool change.

  3. 3

    Set Correct Parameter Value

    Enter the appropriate value for your tool changer configuration and confirm the change.

    Incorrect values may cause tool changer malfunction - consult machine documentation.

  4. 4

    Restart Control

    Perform a control restart (CTRL+ALT+DEL) to activate the new parameter setting.

DIY Feasiblehigh confidence

Call a technician if:

  • ·PLC programming modifications required
  • ·Hardware interface replacement needed
  • ·Multiple related alarms persist after parameter correction

Prevention

  • Regular backup of machine parameters and configurations
  • Verify parameter settings after software updates
  • Monitor PLC program integrity during maintenance

Common Mistakes

  • Setting MP7160 to 0 instead of valid tool changer type
  • Forgetting control restart after parameter changes
  • Modifying PLC code without understanding tool change sequence

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.