HEIDENHAIN 600-02EA - No tool found. Please check drill diameter.
Alarm 600-02EA occurs when the Automatic Workpiece Gaging (AWG) optimization routine determines that all available tools in the tool table are unsuitable for the programmed drilling operations. The system's optimization algorithm has rejected every tool based on diameter, length, or capability mismatches with the AWG requirements.
HEIDENHAIN 600-02EA - No tool found. Please check drill diameter.
No tool found. Please check drill diameter.
No suitable tool was found for the automatic workpiece generation. This may be due to incorrect tool geometry parameters or unsuitable tool types.
Root Cause Summary
Alarm 600-02EA occurs when the Automatic Workpiece Gaging (AWG) optimization routine determines that all available tools in the tool table are unsuitable for the programmed drilling operations. The system's optimization algorithm has rejected every tool based on diameter, length, or capability mismatches with the AWG requirements.
Safety
Causes and Fixes
Access tool table
Press TOOL TABLE key, then select 'Tool data' to view current tool definitions and their diameter values (DL column).
Sort by tool type to quickly identify all drilling tools
Verify drill specifications
Check the drill diameter entries against the programmed hole sizes in your NC program, ensuring DL values match required hole diameters within tolerance.
Incorrect diameter values can cause tool breakage or poor hole quality
Update tool data
Correct any mismatched diameter values in the DL column, ensuring tools are properly categorized with TYPE=DRILL in the tool table.
Reload AWG optimization
Restart the AWG cycle to allow the optimization routine to re-evaluate the corrected tool data.
Call a technician if:
Prevention
Common Mistakes
Related Alarms
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.