Heidenhain codes
HeidenhainToolIntermediate30-120 minutes

600-00B5

HEIDENHAIN 600-00B5 - Unknown tool type defined! No automatic tool selection possible.

Unknown tool type defined! No automatic tool selection possible.

A tool-related error occurred during automatic operation. The tool may have incorrect parameters or may not be suitable for the operation.

Root Cause Summary

Alarm 600-00B5 occurs when the TNC control encounters an undefined or invalid tool type in the tool table that prevents automatic tool selection. This typically happens when tool type parameters are incorrectly configured or corrupted in the TOOL.T table.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access Tool Table

    Press MOD key, select 'Tables' and open TOOL.T table to view all tool entries.

    Use Ctrl+F to quickly search for the problematic tool number shown in %1 parameter

  2. 2

    Check Tool Type Column

    Examine the 'TYPE' column for the affected tool. Valid types are typically 0-32 (mill), 10-19 (drill), 20-29 (tap), etc.

    Never modify tool table while program is running

  3. 3

    Correct Tool Type Value

    Enter valid tool type number based on actual tool geometry. Reference machine manual for specific type definitions.

    Type 0 (end mill) is safest default for unknown cutting tools

  4. 4

    Save and Reset

    Press END key to save changes, then cycle power or press CTRL+ALT+DEL to reset control.

    Always backup tool table before making changes

DIY Feasiblehigh confidence

Call a technician if:

  • ·Machine parameter access unavailable
  • ·Repeated table corruption
  • ·Software compatibility issues persist

Prevention

  • Regular tool table backups
  • Validate tool types after software updates
  • Use standardized tool type numbering system
  • Monitor for file system errors

Common Mistakes

  • Using custom tool type numbers without parameter setup
  • Ignoring backup procedures
  • Mixing tool type standards
  • Not verifying changes in test mode first

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.