Heidenhain codes
HeidenhainSpindleIntermediate30-120 minutes

292-0010

HEIDENHAIN 292-0010 - CMO is not in the current kinematic description

CMO is not in the current kinematic description

The collision monitored object cannot be found in the currently selected kinematics description.

Root Cause Summary

HEIDENHAIN alarm 292-0010 occurs when attempting to activate/deactivate a Collision Monitored Object (CMO) that is not defined in the currently active kinematic description. This typically happens after kinematic changes, CMO deletions, or incorrect CMO references in the collision monitoring setup.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check active kinematic description

    Navigate to Setup > Machine > Kinematics and verify the currently loaded kinematic file name and CMO definitions.

    Note down the exact kinematic file name for cross-reference

  2. 2

    Verify CMO definitions in kinematic file

    Access the kinematic description file and check if the referenced CMO exists in the collision object definitions section.

    Do not modify kinematic files without proper backup and machine manufacturer approval

  3. 3

    Update collision monitoring setup

    Go to Setup > Collision Monitoring and remove references to the non-existent CMO or redefine the CMO in the kinematic description.

    Use the collision monitoring preview function to verify changes before activation

DIY Feasiblehigh confidence

Call a technician if:

  • ·Kinematic file corruption requiring manufacturer-specific reconstruction
  • ·Multiple CMO definition errors affecting machine safety

Prevention

  • Always backup kinematic files before modifications
  • Verify CMO names when setting up collision monitoring
  • Document all kinematic changes with CMO impact assessment

Common Mistakes

  • Case-sensitive CMO name entry errors
  • Loading wrong kinematic file after machine modifications
  • Deleting CMOs without updating collision monitoring references

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.