HEIDENHAIN 23A-002F - Error in communication with device

Error in communication with device

This TNC7/TNC 640 error indicates a communication failure with a connected device. FSuC: invalid received data the affected component ID number: the device, serial number: the unit The control cannot establish or maintain proper data exchange.

Root Cause Summary

This alarm is triggered when the TNC control's communication handler detects repeated timeout or data integrity failures when polling a specific device on the PLC/I/O network. The root cause is typically either a physical layer problem (cabling, connectors, termination) or a configuration mismatch between what the control expects and what the device is programmed to provide. Unlike system-wide bus failures, this alarm targets a specific device, making isolation straightforward once the device identity is confirmed.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Identify the affected device

    Note the device name/number shown in the %2 parameter of the alarm message. Cross-reference this with the machine's wiring diagrams to locate the physical device and its connection point on the control cabinet.

    Take a photo of the alarm screen showing the exact device identifier before resetting—this information disappears after acknowledgment.

  2. 2

    Inspect physical connections

    Power down the control, then inspect the specific device cable from the TNC X-port connectors (X116, X126) or PLC expansion connectors to the device. Check for damaged shielding, bent pins, cable strain at connectors, and proper cable gland tightness.

    Always power down before disconnecting EnDat or bus connections to prevent damage to interface electronics.

  3. 3

    Verify bus termination

    For PROFIBUS or PROFINET devices, verify termination resistors are installed only at the physical ends of the bus segment. For EnDat devices, confirm the last encoder has termination enabled if using daisy-chain topology.

    Use a multimeter to measure bus resistance with power off—PROFIBUS should read approximately 110 ohms between A and B lines when properly terminated.

  4. 4

    Test with cable substitution

    Replace the suspect cable with a known-good spare of identical type and length. For EnDat encoders, use only Heidenhain-approved cables with proper impedance. Power up and verify alarm clears.

    If alarm clears immediately, the original cable likely has intermittent shielding breakdown or internal wire fracture invisible to visual inspection.

DIY Feasiblemedium confidence

Call a technician if:

  • ·FSuC hardware replacement required
  • ·TNC network card failure confirmed
  • ·Safety system validation needed after repairs

Prevention

  • Use only Heidenhain-approved FSuC network cables
  • Perform regular FSuC communication diagnostics
  • Maintain proper cable routing away from EMI sources
  • Keep FSuC firmware updated per Heidenhain recommendations

Common Mistakes

  • Using standard Ethernet cables instead of FSuC-specific cables
  • Ignoring EMI sources during installation
  • Mixing FSuC device types without proper configuration
  • Skipping safety validation after communication repairs