Heidenhain codes
HeidenhainServo/AxisIntermediate30-120 minutes

231-C6E0

HEIDENHAIN 231-C6E0 - C6E0 Amplitude test in axis: speed encoder is incorrect, test

C6E0 Amplitude test in axis: speed encoder is incorrect, test

The internal amplitude-monitoring test at the speed-encoder inputs found an error. Causes include a pwmSignalOutput/analogOffset entry that does not match the actual wiring, or a wrong motEncType machine-parameter setting for the connected encoder.

Root Cause Summary

HEIDENHAIN alarm 231-C6E0 indicates the amplitude test for the speed encoder on the specified axis has failed, detecting either amplitude too low or too high conditions. This typically results from encoder configuration mismatches, cable issues, or hardware failures in the speed feedback system.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access Machine Parameters

    Navigate to MOD function → Machine Parameters → Axis-specific parameters for the affected axis.

    Always backup current parameters before making changes

  2. 2

    Verify motEncType Setting

    Check parameter motEncType matches encoder specification. Common values: 0=incremental, 1=EnDat2.1, 2=EnDat2.2, 3=SSI, 4=Fanuc serial.

    Incorrect encoder type can damage encoder or control

  3. 3

    Cross-Reference Encoder Label

    Compare motEncType value with encoder nameplate data and machine documentation to ensure proper configuration.

  4. 4

    Test After Correction

    Clear alarm, perform controlled axis movement, and monitor for alarm recurrence.

DIY Feasiblemedium confidence

Call a technician if:

  • ·CC unit replacement required
  • ·Multiple axes affected simultaneously
  • ·Encoder replacement needed

Prevention

  • Regular encoder cable inspection during PM
  • Maintain proper cable carrier lubrication
  • Monitor encoder signal quality trends
  • Verify parameter backups before changes

Common Mistakes

  • Changing motEncType without verifying encoder specifications
  • Ignoring cable routing near heat sources
  • Skipping signal quality verification after repairs
  • Not backing up parameters before modifications

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.