Heidenhain codes
HeidenhainSystemIntermediate30-120 minutes

231-E002

HEIDENHAIN 231-E002 - E002 Status em.stop input signal not equal to test output: T2

E002 Status em.stop input signal not equal to test output: T2

During the safety self-test, the level of test output T2 did not match the emergency-stop input of the CC. This indicates a wiring or hardware fault in the emergency-stop test circuit.

Root Cause Summary

Alarm 231-E002 indicates a safety circuit mismatch where the emergency stop test output T2 signal level does not match the corresponding emergency stop input signal on the control cabinet. This safety monitoring discrepancy prevents proper emergency stop function verification and triggers an immediate safety alarm.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check Emergency Stop Circuit Status

    Navigate to MOD > Service > PLC Status and monitor emergency stop relay states. Check X121 input signals for proper emergency stop chain continuity.

    Ensure machine is in safe state before checking emergency stop circuits

  2. 2

    Measure Relay Coil Resistance

    Power down and measure emergency stop safety relay K1 coil resistance. Should read per manufacturer specifications (typically 200-500 ohms).

    Check relay part number against Heidenhain approved components list

  3. 3

    Verify Contact Operation

    Manually operate emergency stop and verify all NO/NC contacts change state properly using multimeter. Replace relay if contacts are welded or not switching.

    Use LOTO procedures when testing emergency stop circuits

Service Recommendedmedium confidence

Call a technician if:

  • ·Safety circuit modifications required
  • ·TNC safety module replacement needed
  • ·Unable to clear alarm after basic checks

Prevention

  • Perform monthly emergency stop function tests
  • Keep safety circuit connections clean and tight
  • Monitor safety relay contact wear during PM
  • Maintain proper documentation of safety parameter changes

Common Mistakes

  • Bypassing safety circuits for troubleshooting
  • Ignoring intermittent emergency stop operation
  • Modifying safety parameters without proper authorization
  • Using non-approved replacement safety relays

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.