axismd.ai
Heidenhain Controller
System · Intermediate · 30-120 minutes
HEIDENHAIN 231-E002 - E002 Status em.stop input signal not equal to test output: T2
Alarm 231-E002 indicates a safety circuit mismatch where the emergency stop test output T2 signal level does not match the corresponding emergency stop input signal on the control cabinet. This safety monitoring discrepancy prevents proper emergency stop function verification and triggers an immediate safety alarm.
HEIDENHAIN 231-E002 - E002 Status em.stop input signal not equal to test output: T2
E002 Status em.stop input signal not equal to test output: T2
During the safety self-test, the level of test output T2 did not match the emergency-stop input of the CC. This indicates a wiring or hardware fault in the emergency-stop test circuit.
Root Cause Summary
Alarm 231-E002 indicates a safety circuit mismatch where the emergency stop test output T2 signal level does not match the corresponding emergency stop input signal on the control cabinet. This safety monitoring discrepancy prevents proper emergency stop function verification and triggers an immediate safety alarm.
Safety
Causes and Fixes
Check Emergency Stop Circuit Status
Navigate to MOD > Service > PLC Status and monitor emergency stop relay states. Check X121 input signals for proper emergency stop chain continuity.
Ensure machine is in safe state before checking emergency stop circuits
Measure Relay Coil Resistance
Power down and measure emergency stop safety relay K1 coil resistance. Should read per manufacturer specifications (typically 200-500 ohms).
Check relay part number against Heidenhain approved components list
Verify Contact Operation
Manually operate emergency stop and verify all NO/NC contacts change state properly using multimeter. Replace relay if contacts are welded or not switching.
Use LOTO procedures when testing emergency stop circuits
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.