HEIDENHAIN 231-E000 - E000 Start test of the cut-out channels not possible
HEIDENHAIN alarm 231-E000 occurs when the PLC attempts to initiate safety cut-out channel testing while the TNC control is not in AUTO mode or axis motors remain energized. This safety interlock prevents diagnostic testing during inappropriate machine states.
HEIDENHAIN 231-E000 - E000 Start test of the cut-out channels not possible
E000 Start test of the cut-out channels not possible
The PLC could not start the test of the cut-out channels because the control is not in the AUTO state, or the motors of at least one axis group have not yet been switched off.
Root Cause Summary
HEIDENHAIN alarm 231-E000 occurs when the PLC attempts to initiate safety cut-out channel testing while the TNC control is not in AUTO mode or axis motors remain energized. This safety interlock prevents diagnostic testing during inappropriate machine states.
Safety
Causes and Fixes
Check current operating mode
Press the operating mode keys and verify the AUTO LED is illuminated on the TNC control panel.
The mode display also appears in the status bar of the TNC screen
Switch to AUTO mode
Press the AUTO key on the machine control panel to activate automatic mode operation.
Ensure machine is in safe position before switching modes
Verify mode transition
Confirm AUTO mode is active and check if alarm clears automatically after mode change.
Some machines require a brief delay for mode recognition
Reset alarm if persistent
Press CE key to clear the alarm after confirming AUTO mode is properly selected.
Call a technician if: