HEIDENHAIN 231-E019 - E019 CC SPLC configuration error ERR-ID=

E019 CC SPLC configuration error ERR-ID=

The SPLC safety configuration is faulty. Depending on the alarm ID, this is an internal software error, an invalid value in one of the CfgSafety machine parameters, or a mismatch between the installed NC software version and the SplcApiMarker.def file used in the SPLC project.

Root Cause Summary

This alarm stems from a configuration data integrity issue between the NC kernel and the integrated Safety PLC, typically triggered during initialization when the NC validates safety-critical parameters. The ERR-ID parameter provides a specific fault code that identifies which aspect of the SPLC configuration has failed validation, whether due to file corruption, version mismatch, or communication errors in the safety data exchange.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check Firmware and Safety Versions

    Enter MOD mode, select 'System Information' and document the NC software version. Then navigate to 'Safety' submenu and record the Safety PLC version and configuration date. Compare these against machine documentation.

    Safety configuration version must match or be compatible with NC firmware version - check Heidenhain technical documentation for compatibility matrix.

  2. 2

    Access Safety Configuration Status

    In MOD function, select 'Safety Configuration' then 'Status Display'. Look for red indicators or error messages. Note the configuration checksum displayed and compare with documented value.

    Do not modify safety parameters without proper authorization and safety training - this may void machine certification.

  3. 3

    Restore Compatible Safety Configuration

    Using TNCbackup or Programming Station, restore the safety configuration files (.SPL, .SEC) from the backup matching your current firmware version. Files are located in SYS:\SAFETY directory.

    Always maintain version-matched backup sets containing both NC parameters and safety configuration files together.

  4. 4

    Perform Safety Configuration Validation

    After restoration, in MOD mode navigate to Safety Configuration and select 'Validate Configuration'. The system will perform CRC check and compatibility verification. Power cycle after successful validation.

    Safety validation requires machine in safe state with all axes referenced and safety circuits functional.

Service Recommendedlow confidence

Call a technician if:

  • ·Any safety parameter modifications required
  • ·Software version mismatches detected
  • ·Safety system re-validation needed

Prevention

  • Document all safety parameter changes during commissioning
  • Implement change control for NC software updates
  • Monitor SPLC resource usage during development
  • Maintain backup of validated safety configuration

Common Mistakes

  • Modifying safety parameters without proper authorization
  • Updating NC software without safety system consideration
  • Exceeding SPLC resource limits during program development
  • Ignoring transfer area limit warnings