HEIDENHAIN 231-E02B - E02B SKERN-CC: Dynamisierungtest sicherer PL-Eingang: fehlerhaft

E02B SKERN-CC: Dynamisierungtest sicherer PL-Eingang: fehlerhaft

The dynamic test of the PLC peripheral devices found that a safe PL input did not switch to the 0 level as required. Possible reasons include an incorrect SMP587 machine-parameter entry, wiring errors of the test groups or test outputs, an IOC configuration-file error, or disturbed HSCI communication.

Root Cause Summary

Alarm 231-E02B indicates a failure in the dynamic safety test of PLC peripheral inputs, where a safety-relevant input failed to switch to the 0 level during the SKERN-CC safety kernel test cycle. This typically occurs due to incorrect safety machine parameters, wiring errors in test groups, or HSCI communication disturbances affecting the safety circuit validation.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access Safety Machine Parameters

    Navigate to MOD > Machine Parameters > Safety Parameters and locate SMP587 (Safety Input Test Configuration).

    Document current SMP587 values before making changes for rollback purposes.

  2. 2

    Verify SMP587 Configuration

    Check SMP587 bit settings against machine documentation. Verify test group assignments and input polarity settings match actual hardware configuration.

    Incorrect safety parameter changes can compromise machine safety - consult machine documentation.

  3. 3

    Validate Test Group Settings

    Cross-reference SMP587 test group configuration with actual PLC input wiring and safety circuit design.

    Use TNCdiag to monitor real-time safety input states during parameter verification.

  4. 4

    Reset Safety System

    After parameter correction, perform safety system reset via MOD > Reset > Safety Reset to reinitialize SKERN-CC test cycles.

Service Recommendedmedium confidence

Call a technician if:

  • ·Safety parameter modifications required
  • ·IOC file corruption detected
  • ·Persistent HSCI communication failures
  • ·Wiring modifications needed

Prevention

  • Regular HSCI communication monitoring
  • Periodic safety parameter backup
  • IOC file version control
  • Scheduled safety circuit testing

Common Mistakes

  • Modifying SMP587 without understanding test group implications
  • Ignoring HSCI communication quality degradation
  • Incorrect IOC file restoration after updates
  • Bypassing safety input testing during troubleshooting