HEIDENHAIN 231-E130 - E130 Test current is too small

E130 Test current is too small

The test current measured during the safety self-test is too low. The current control loop may not be adjusted, drive enabling may have been missing at the PWM output during the measurement, or the current sensor may be defective.

Root Cause Summary

HEIDENHAIN alarm 231-E130 occurs when the safety self-test detects insufficient test current in the servo drive system. This typically indicates problems with current control loop calibration, PWM drive enabling, or defective current sensors in the MC or CC unit.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access current control parameters

    Navigate to MOD function → Machine Parameters → Axis-specific parameters → Current control settings for the affected axis.

    Document original parameter values before making changes

  2. 2

    Check MP1020 current control parameters

    Verify MP1020.x (current controller gain) and MP1021.x (current controller time constant) are within manufacturer specifications for your motor type.

    Incorrect current control settings can damage servo motors

  3. 3

    Perform current control optimization

    Execute the automatic current control adjustment via Setup → Servo → Current Control → Auto Adjustment for the affected axis.

    Ensure motor is at operating temperature before optimization

  4. 4

    Verify test current measurement

    Run safety self-test via Diagnosis → Servo → Safety Test to confirm test current now meets minimum threshold requirements.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Current sensor calibration fails repeatedly
  • ·PWM output stage hardware failure suspected
  • ·Motor winding damage confirmed

Prevention

  • Perform regular current control calibration during scheduled maintenance
  • Monitor current sensor drift trends in diagnostic logs
  • Maintain proper motor cable torque specifications

Common Mistakes

  • Attempting calibration with motor at incorrect temperature
  • Ignoring PWM enable signal timing requirements
  • Not documenting original parameter values before adjustments