Heidenhain codes
HeidenhainServo/AxisIntermediate30-120 minutes

231-4810

Heidenhain 231-4810 - 4810 CC (log): actual current value too high

4810 CC (log): actual current value too high

Heidenhain error 231-4810: 4810 CC (log): actual current value too high. The motor or drive current has exceeded the rated limit. The protection circuit has tripped to prevent motor and drive damage.

Root Cause Summary

Alarm 231-4810 indicates the actual current value in the servo drive has exceeded the maximum allowable threshold. This typically occurs due to mechanical binding, excessive cutting loads, or servo drive parameter misconfiguration causing overcurrent conditions.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check Axis Movement

    Use Manual Operation mode to jog each axis slowly and check for binding, unusual noise, or resistance.

    Move axes at reduced feedrate (10-25%) to avoid damage

  2. 2

    Inspect Mechanical Components

    Check ball screws, linear guides, and coupling for debris, damage, or inadequate lubrication.

    Look for metal chips or coolant buildup on linear guides

  3. 3

    Verify Machine Geometry

    Check if workpiece, fixture, or tool is interfering with machine travel using Setup > Position Display.

    Use 3D tool path simulation if available to verify clearances

DIY Feasiblemedium confidence

Call a technician if:

  • ·Motor or drive hardware replacement needed
  • ·Servo parameter tuning required
  • ·Mechanical repairs beyond basic maintenance

Prevention

  • Regular lubrication of linear guides and ball screws
  • Monitor cutting tool condition
  • Maintain proper chip evacuation
  • Periodic review of actual vs. programmed current values

Common Mistakes

  • Ignoring gradual increase in current draw before alarm
  • Adjusting current limits without addressing root cause
  • Not checking for mechanical binding before parameter changes
  • Overlooking encoder signal quality issues

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.