Heidenhain codes
HeidenhainServo/AxisIntermediate30-120 minutes

231-6100

Heidenhain 231-6100 - 6100 Cut-out channel test: Status change -STO.A.x = 0->1

6100 Cut-out channel test: Status change -STO.A.x = 0->1

Heidenhain TNC error 231-6100: 6100 Cut-out channel test: Status change -STO.A.x = 0->1. This alarm indicates a fault or error condition on the Heidenhain TNC control that requires investigation. Refer to the Heidenhain NC error message documentation for the specific cause and remedy for this alarm code.

Root Cause Summary

Alarm 231-6100 indicates a Safe Torque Off (STO) status change from inactive (0) to active (1) on axis channel A.x during cut-out channel monitoring. This safety-related alarm triggers when the TNC detects an unexpected STO activation, typically due to external safety circuit interruption or drive amplifier safety function engagement.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check External Safety Devices

    Verify all E-stop buttons are released, safety doors are closed, and light curtains are clear. Check safety relay status in PLC diagnostics.

    Do not bypass safety devices - resolve the actual safety condition first

  2. 2

    Inspect Safety Circuit Wiring

    Check 24V safety circuit continuity from safety relays to drive STO inputs. Measure voltage at drive terminals X3/1 and X3/2 (STO+ and STO-).

    STO circuit should show 24V when active - 0V indicates safety circuit interruption

  3. 3

    Reset Safety System

    After clearing safety conditions, reset the safety system and acknowledge alarm using ALARM key, then press CE to clear the message.

    Some systems require specific reset sequence - check machine manual for proper safety reset procedure

DIY Feasiblehigh confidence

Call a technician if:

  • ·Safety parameter modification required
  • ·Drive amplifier replacement needed
  • ·Persistent communication errors after cable replacement

Prevention

  • Regular safety circuit testing
  • Periodic drive parameter backup
  • Environmental monitoring for temperature/vibration
  • Scheduled EnDat cable inspection

Common Mistakes

  • Bypassing safety devices instead of fixing root cause
  • Ignoring drive thermal conditions
  • Not checking safety circuit voltage levels
  • Modifying safety parameters without proper documentation

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.