Heidenhain codes
HeidenhainServo/AxisIntermediate30-120 minutes

231-6810

Heidenhain 231-6810 - 6810 CC (Dbg): switch-off position invalid, outside the limit switches

6810 CC (Dbg): switch-off position invalid, outside the limit switches

Heidenhain error 231-6810: 6810 CC (Dbg): switch-off position invalid, outside the limit switches. The axis position following error has exceeded the allowable tolerance. The actual axis position has deviated too far from the commanded position, indicating a servo control problem or mechanical issue.

Root Cause Summary

Alarm 231-6810 occurs when the control detects that an axis switch-off position is located outside the configured limit switch boundaries during system diagnostics. This typically happens during reference point establishment or axis initialization when the stored switch-off position conflicts with the current limit switch settings.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check reference point status

    Navigate to MOD function and check the reference point status display. Look for missing reference marks or error indicators on the affected axis.

    Press CTRL+R to quickly access reference point information

  2. 2

    Perform manual reference run

    Execute a manual reference point approach using the reference point menu. Select the affected axis and initiate reference run sequence.

    Ensure axis can move freely and no obstacles are present before starting reference run

  3. 3

    Verify reference point establishment

    After successful reference run, check that the position display shows correct absolute coordinates and the reference point indicator is active.

    Compare current position with expected machine zero position from setup documentation

DIY Feasiblehigh confidence

Call a technician if:

  • ·Encoder replacement required
  • ·Machine parameter backup needed
  • ·Multiple axes affected simultaneously

Prevention

  • Regular backup of machine parameters
  • Periodic limit switch inspection
  • Maintain clean encoder environment

Common Mistakes

  • Modifying limits without understanding switch-off position
  • Ignoring reference point status
  • Assuming hardware is always correct

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.