Heidenhain 231-6016 - 6016 STOP2 release: Incorrect power supply

6016 STOP2 release: Incorrect power supply

Heidenhain TNC error 231-6016: 6016 STOP2 release: Incorrect power supply. This alarm indicates a fault or error condition on the Heidenhain TNC control that requires investigation. Refer to the Heidenhain NC error message documentation for the specific cause and remedy for this alarm code.

Root Cause Summary

HEIDENHAIN alarm 231-6016 indicates an incorrect power supply voltage to the STOP2 release circuit, typically caused by voltage deviations outside the specified 24VDC ±10% range. This alarm protects the safety circuit integrity by monitoring the power supply quality to critical safety components.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check Power Supply Voltage

    Navigate to MOD > SYSTEM > DIAGNOSIS > VOLTAGE and verify 24VDC supply reads between 21.6V-26.4V under load conditions.

    Check voltage during spindle acceleration when power demand peaks

  2. 2

    Measure at Terminal Strip

    Using DMM, measure 24VDC at X116 terminals (typically pins 1-2) on the TNC control cabinet terminal strip during machine operation.

    Ensure proper lockout/tagout procedures before accessing electrical panels

  3. 3

    Load Test Power Supply

    Connect temporary load resistor across 24VDC output and verify voltage stability. Replace power supply if voltage drops below 21.6V under rated load.

    Use 24V/10W automotive bulb as quick load test

DIY Feasiblehigh confidence

Call a technician if:

  • ·Safety module replacement required
  • ·Power supply replacement needed
  • ·Persistent alarm after all checks

Prevention

  • Monthly 24VDC voltage monitoring
  • Annual safety circuit inspection
  • Keep EMI sources away from control cabinet

Common Mistakes

  • Ignoring voltage drop measurements
  • Not checking under load conditions
  • Mixing safety and non-safety circuits