Heidenhain 231-6003 - 6003 Status of machine-on input = 0 after "hcSgMaschineEin"

6003 Status of machine-on input = 0 after "hcSgMaschineEin"

Heidenhain TNC error 231-6003: 6003 Status of machine-on input = 0 after "hcSgMaschineEin". This alarm indicates a fault or error condition on the Heidenhain TNC control that requires investigation. Refer to the Heidenhain NC error message documentation for the specific cause and remedy for this alarm code.

Root Cause Summary

Alarm 231-6003 occurs when the machine-on input signal drops to 0 after the hcSgMaschineEin command has been executed. This indicates a loss of the machine enable signal during operation, typically due to hardware failures in the enable chain or safety circuit interruptions.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check Machine Enable Relay Status

    Navigate to MOD function → Machine Parameters → MP7300.x series to verify enable relay status and check physical relay K1 in electrical cabinet.

    Ensure main power is locked out before checking relay contacts

  2. 2

    Verify Enable Chain Continuity

    Use multimeter to check continuity through complete enable chain from TNC to servo drives, including all safety relays in series.

    Check MP7310.0 (Machine ON input) parameter assignment matches actual hardware wiring

  3. 3

    Test Relay Coil Voltage

    Measure 24VDC supply to enable relay coil and verify proper switching voltage levels at relay contacts.

    Intermittent voltage drops often cause this alarm during high current draw operations

DIY Feasiblehigh confidence

Call a technician if:

  • ·TNC input module replacement required
  • ·Safety circuit modifications needed
  • ·Complex PLC programming changes required

Prevention

  • Regular 24VDC supply voltage monitoring
  • Periodic safety circuit testing
  • Annual relay contact inspection
  • Maintain proper electrical cabinet ventilation

Common Mistakes

  • Bypassing safety circuits instead of fixing root cause
  • Not checking voltage under load conditions
  • Ignoring intermittent connection issues
  • Failing to document parameter changes during troubleshooting