HEIDENHAIN 230-0497 - Incorrect inverter or motor connection (, inv., motor)
This alarm occurs when the TNC control's drive system detects an incompatibility between the configured inverter power stage and the motor parameters. The drive controller cannot safely operate because the electrical matching between power module and motor is incorrect or undefined, typically due to configuration errors, wrong motor assignment, or failed motor identification.
HEIDENHAIN 230-0497 - Incorrect inverter or motor connection (, inv., motor)
Incorrect inverter or motor connection (, inv., motor)
The inverter or motor connection is misconfigured. The specified interface may not exist, no inverter is connected, or the motor connector is wrong.
Root Cause Summary
This alarm occurs when the TNC control's drive system detects an incompatibility between the configured inverter power stage and the motor parameters. The drive controller cannot safely operate because the electrical matching between power module and motor is incorrect or undefined, typically due to configuration errors, wrong motor assignment, or failed motor identification.
Safety
Causes and Fixes
Access Drive Configuration in MOD
Power on in Service Mode, press MOD key, navigate to 'Drive System' or 'Motor Configuration' menu. Identify the axis/spindle and inverter/motor numbers from the alarm text.
Document existing settings before making changes. Incorrect motor parameters can cause dangerous motor behavior.
Verify Motor Nameplate Data
Check physical motor nameplate for rated voltage, current, power, pole pairs, and encoder type. Compare these values with the parameters in MOD > Motor Parameters for the affected motor number.
For synchronous motors, pay special attention to pole pair count - this is critical for commutation and often misconfigured during motor replacement.
Correct Motor Configuration Parameters
In MOD function, enter correct values for motor type, rated current, rated voltage, pole pairs, encoder type, and thermal monitoring parameters to match motor nameplate.
Heidenhain motors typically have configuration data on a label or in documentation - use exact values rather than estimating.
Save Configuration and Test
Save the corrected motor parameters in MOD, perform a complete controller restart (power cycle), and verify alarm clears. Test axis motion at low feedrate (10%) initially.
Call a technician if:
Prevention
Common Mistakes
Related Alarms
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.