Heidenhain codes
HeidenhainParameterIntermediate30-120 minutes

230-04B3

HEIDENHAIN 230-04B3 - More safe axes are activated than are enabled in the SIK

More safe axes are activated than are enabled in the SIK

More safe axes are active than enabled by SIK axis options. The machine configuration exceeds licensed safe axis count.

Root Cause Summary

Alarm 230-04B3 occurs when the machine configuration defines more safe axes than the Software Installation Key (SIK) permits. This is a licensing mismatch between the purchased axis options and the configured safe axes in the TNC control.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check SIK axis options

    Access MOD function, select 'System info' and review the licensed axis options in the SIK display to determine maximum allowed safe axes.

    Document the exact SIK axis configuration before making changes

  2. 2

    Review safe axis configuration

    Navigate to Setup → Machine → Config → Axes and check MP7500.x parameters to count how many axes are configured with safe axis functionality enabled.

    Do not modify MP7500 parameters without machine manufacturer approval

  3. 3

    Disable excess safe axes

    In MP7500.x series, set unnecessary safe axis configurations to 'NO' for axes that don't require safety functions, ensuring total doesn't exceed SIK limit.

    Prioritize keeping safety functions on primary motion axes (X, Y, Z)

  4. 4

    Restart control system

    Perform a complete TNC restart to reinitialize the axis configuration and clear the alarm condition.

DIY Feasiblehigh confidence

Call a technician if:

  • ·SIK upgrade required
  • ·Machine parameter documentation unavailable
  • ·Safety system integration concerns

Prevention

  • Maintain SIK backup files
  • Document all MP7500 parameter changes
  • Verify axis licensing before configuration changes

Common Mistakes

  • Enabling safe axes on non-critical axes
  • Not checking SIK limits before parameter changes
  • Using incorrect SIK files

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.