HEIDENHAIN 230-04C4 - Two brake outputs refer to the same brake
HEIDENHAIN alarm 230-04C4 occurs when multiple brake outputs in the IOCP configuration file reference the same CfgBrake parameter. This creates a conflict where two different brake control outputs attempt to control the same physical brake system.
HEIDENHAIN 230-04C4 - Two brake outputs refer to the same brake
Two brake outputs refer to the same brake
Two brake outputs in the IOCP file reference the same brake. Each brake should have only one output.
Root Cause Summary
HEIDENHAIN alarm 230-04C4 occurs when multiple brake outputs in the IOCP configuration file reference the same CfgBrake parameter. This creates a conflict where two different brake control outputs attempt to control the same physical brake system.
Safety
Causes and Fixes
Access IOCP configuration
Navigate to MOD > System Parameters > IOCP Configuration to examine brake output assignments.
Always backup the current IOCP file before making changes
Identify duplicate brake references
Search for all instances of 'CfgBrake' parameters and identify which brake number (%1 from alarm) appears multiple times.
Document all current brake assignments before modification
Reassign brake output references
Modify one of the conflicting brake outputs to reference a different CfgBrake number or remove the duplicate assignment.
Ensure each physical brake has only one corresponding CfgBrake reference
Validate IOCP configuration
Save changes and restart the TNC to verify the alarm clears and brake functionality operates correctly.
Call a technician if:
Prevention
Common Mistakes
Related Alarms
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.