axismd.ai
Heidenhain Controller
Servo/Axis · Intermediate · 30-120 minutes
HEIDENHAIN 230-04CA - Braking connection for brake incorrectly configured
HEIDENHAIN alarm 230-04CA occurs when the brake connection parameter CfgBrake/MP_connection contains an invalid value or references a non-existent I/O connection. This typically happens during initial machine setup or after configuration changes to the brake control system.
HEIDENHAIN 230-04CA - Braking connection for brake incorrectly configured
Braking connection for brake incorrectly configured
The CfgBrake/MP_connection parameter contains an incorrect value for the brake connection.
Root Cause Summary
HEIDENHAIN alarm 230-04CA occurs when the brake connection parameter CfgBrake/MP_connection contains an invalid value or references a non-existent I/O connection. This typically happens during initial machine setup or after configuration changes to the brake control system.
Safety
Causes and Fixes
Access brake configuration
Navigate to MOD function → Machine Parameters → CfgBrake section to view current brake configuration parameters.
Use Ctrl+F to quickly search for 'CfgBrake' in the parameter list
Verify MP_connection value
Check the MP_connection parameter value against the available I/O connections in your system documentation. Valid values typically range from 0-15 depending on PLC configuration.
Never change brake parameters without proper safety lockout procedures
Correct parameter value
Set MP_connection to the correct I/O connection number as specified in your machine's electrical documentation.
Cross-reference with PLC I/O assignment list to ensure correct mapping
Restart control
Perform a complete TNC restart to activate the new brake configuration parameters.
Call a technician if:
Prevention
Common Mistakes