Heidenhain codes
HeidenhainServo/AxisIntermediate30-120 minutes

230-04CA

HEIDENHAIN 230-04CA - Braking connection for brake incorrectly configured

Braking connection for brake incorrectly configured

The CfgBrake/MP_connection parameter contains an incorrect value for the brake connection.

Root Cause Summary

HEIDENHAIN alarm 230-04CA occurs when the brake connection parameter CfgBrake/MP_connection contains an invalid value or references a non-existent I/O connection. This typically happens during initial machine setup or after configuration changes to the brake control system.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access brake configuration

    Navigate to MOD function → Machine Parameters → CfgBrake section to view current brake configuration parameters.

    Use Ctrl+F to quickly search for 'CfgBrake' in the parameter list

  2. 2

    Verify MP_connection value

    Check the MP_connection parameter value against the available I/O connections in your system documentation. Valid values typically range from 0-15 depending on PLC configuration.

    Never change brake parameters without proper safety lockout procedures

  3. 3

    Correct parameter value

    Set MP_connection to the correct I/O connection number as specified in your machine's electrical documentation.

    Cross-reference with PLC I/O assignment list to ensure correct mapping

  4. 4

    Restart control

    Perform a complete TNC restart to activate the new brake configuration parameters.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Hardware replacement required
  • ·PLC programming changes needed
  • ·Safety system integration issues

Prevention

  • Regular backup of machine parameters
  • Document all brake configuration changes
  • Verify I/O connections during maintenance

Common Mistakes

  • Changing brake parameters without safety lockout
  • Not restarting TNC after parameter changes
  • Ignoring PLC program compatibility

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.