axismd.ai
Heidenhain Controller
Servo/Axis · Intermediate · 30-120 minutes
HEIDENHAIN 230-04CD - Error during conversion of motor
This alarm indicates the TNC control's parameter conversion engine failed to translate motor configuration data from one format to another, typically during software migration. The conversion process validates and maps legacy motor parameters to new data structures, and fails when encountering incompatible, corrupted, or out-of-specification parameter values that cannot be automatically translated.
HEIDENHAIN 230-04CD - Error during conversion of motor
Error during conversion of motor
Motor data conversion from the old PLC motor table to MOTOR_OEM failed. The upgrade process encountered an error.
Root Cause Summary
This alarm indicates the TNC control's parameter conversion engine failed to translate motor configuration data from one format to another, typically during software migration. The conversion process validates and maps legacy motor parameters to new data structures, and fails when encountering incompatible, corrupted, or out-of-specification parameter values that cannot be automatically translated.
Safety
Causes and Fixes
Identify software versions involved
Access MOD function, navigate to System Info and document current NC software version. Compare against the previous version from your service documentation to identify the version jump that triggered conversion.
TNC controls store previous software version info in TNC:\system\changelog.txt - this helps identify exactly which firmware transition caused the issue.
Access machine parameter backup
Navigate to TNC:\system\backup\ directory using PGM MGT key. Locate the automatic backup file created before firmware update (usually named with date/time stamp and .BCK or .BIN extension). Copy this to external media before proceeding.
Do not overwrite current parameters until you've documented all current settings - the backup may not contain your most recent tuning adjustments.
Export current motor parameters manually
Press MOD key > Machine Parameters > activate 'Single Axis Display' for the motor indicated in %1. Document all parameters in groups MP700-MP799 (axis-specific) and MP1000-MP1999 (encoder/motor). Screenshot or write down all non-zero values.
Use MOD > Machine Parameters > Print function to generate a complete parameter list to USB stick - this creates a searchable text file.
Re-enter motor configuration using wizard
In MOD function, select Motor Configuration Wizard. Choose the affected axis, select 'Delete current configuration', then 'New Motor Setup'. Input motor manufacturer, model number from nameplate. Let the wizard populate from Heidenhain motor database rather than converting old parameters.
If your exact motor model isn't in the database, select 'User-defined motor' and manually enter nameplate data - this bypasses the conversion process entirely.
Verify encoder compatibility settings
Check MP1420 (encoder type) matches your actual feedback device. After firmware updates, encoder type enumerations sometimes change. Verify against physical encoder label and update if needed. Cycle power after changing encoder type parameters.
Incorrect encoder type settings can cause position loss or runaway conditions. Ensure amplifier enable is OFF before cycling power with changed encoder parameters.
Call a technician if: