230-04C8

HEIDENHAIN 230-04C8 - Braking connection for brake not configured

Braking connection for brake not configured

This TNC7/TNC 640 error indicates an issue with 230-04C8. Configuration of the brake connection is missing in CfgBrake/MP_connection.

Root Cause Summary

Alarm 230-04C8 occurs when the TNC control cannot find the proper brake connection configuration in the CfgBrake machine parameter file. This typically happens when the MP_connection parameter for the specified brake axis is missing, incorrectly defined, or references a non-existent I/O connection in the PLC configuration.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access machine parameter editor

    Press MOD key, select 'Machine Parameters', navigate to CfgBrake section using the parameter tree.

    Use Ctrl+F to quickly search for 'CfgBrake' in the parameter list

  2. 2

    Locate brake configuration

    Find the brake entry matching the alarm's %2 value (brake number) and check for MP_connection parameter presence.

    Document current settings before making changes

  3. 3

    Add missing MP_connection

    Create new MP_connection parameter with appropriate I/O address referencing the brake control output in your PLC configuration.

    Consult machine documentation for correct I/O mapping before assignment

  4. 4

    Validate and restart

    Save parameters, perform PLC restart via MOD > PLC > Restart, then cycle control power to activate new brake configuration.

DIY Feasiblehigh confidence

Call a technician if:

  • ·PLC programming modifications required
  • ·Hardware I/O failures detected
  • ·Multiple brake systems affected simultaneously

Prevention

  • Regular backup of machine parameters
  • Document all I/O assignments during installation
  • Verify brake configuration after software updates

Common Mistakes

  • Confusing brake number with axis number in configuration
  • Forgetting PLC restart after parameter changes
  • Using input addresses instead of output addresses for brake control