Heidenhain codes
HeidenhainParameterIntermediate30-120 minutes

230-01BB

HEIDENHAIN 230-01BB - Input X for axis is already assigned to another axis.

Input X for axis is already assigned to another axis.

The PWM output assigned to this axis is already in use by another axis. Each axis needs a unique PWM signal channel.

Root Cause Summary

HEIDENHAIN alarm 230-01BB occurs when the CfgAxes->ParamSet->pwmSignalOutput parameter references a PWM output channel that is already assigned to another axis in the TNC configuration. This creates a resource conflict where multiple axes attempt to use the same physical PWM output signal.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access Machine Parameter Configuration

    Navigate to MOD function -> Machine Parameters -> CfgAxes configuration menu in the TNC control.

    Ensure machine is in a safe state before accessing configuration parameters.

  2. 2

    Review PWM Signal Output Assignments

    Check each axis ParamSet->pwmSignalOutput parameter value. Document which axes are assigned to the same PWM output number.

    Use the TNC's parameter search function to quickly locate all pwmSignalOutput parameters across axes.

  3. 3

    Reassign Conflicting PWM Outputs

    Modify the pwmSignalOutput parameter for conflicting axes to use unique, available PWM output channels according to your hardware configuration.

    Consult the machine's electrical documentation to verify available PWM outputs before reassignment.

  4. 4

    Validate Configuration and Restart

    Save the modified CfgAxes parameters and perform a control restart to verify the alarm clears and axes initialize properly.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Configuration restoration fails repeatedly
  • ·Hardware wiring discrepancies discovered
  • ·Multiple related servo alarms appear

Prevention

  • Always backup CfgAxes before modifications
  • Document PWM assignments during hardware changes
  • Verify configuration after software updates

Common Mistakes

  • Assuming PWM outputs are interchangeable without checking hardware
  • Not backing up configuration before changes
  • Ignoring physical wiring when modifying parameters

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.