Heidenhain codes
HeidenhainServo/AxisIntermediate30-120 minutes

230-01BA

HEIDENHAIN 230-01BA - Input X for axis is already assigned to another axis.

Input X for axis is already assigned to another axis.

The speed-encoder input specified for this axis is already allocated to another axis. Two axes cannot share the same speed-encoder channel.

Root Cause Summary

Alarm 230-01BA occurs when the speedEncoderInput parameter in CfgAxes configuration references an encoder input that is already assigned to another axis. This creates a conflict in the TNC's axis configuration where multiple axes attempt to use the same physical encoder input connection.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access Machine Parameters

    Navigate to MOD function → Machine Parameters → CfgAxes configuration menu to review axis parameter settings.

    Use the search function in machine parameters to quickly locate speedEncoderInput parameters across all axes.

  2. 2

    Check Speed Encoder Assignments

    Review ParamSet→speedEncoderInput parameter for each configured axis and identify which axes share the same input number.

    Document current settings before making changes to avoid losing working configurations.

  3. 3

    Reassign Conflicting Input

    Change the speedEncoderInput parameter for one of the conflicting axes to an unused encoder input number.

    Verify physical encoder connections match the parameter assignments before finalizing changes.

  4. 4

    Validate Configuration

    Save parameters and restart the TNC to verify the alarm clears and all axes function correctly with their assigned encoder inputs.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Physical encoder wiring modifications required
  • ·Hardware compatibility issues discovered
  • ·Multiple related alarms persist after parameter corrections

Prevention

  • Maintain accurate documentation of encoder input assignments
  • Use systematic parameter backup procedures before configuration changes
  • Implement parameter verification checklists for axis setup

Common Mistakes

  • Assuming backup parameters match current hardware
  • Not verifying physical connections before parameter changes
  • Copying axis parameters without updating input-specific values

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.