HEIDENHAIN 230-01BF - Encoder type not permitted for axis
HEIDENHAIN alarm 230-01BF occurs when there is an incompatible configuration between the axis hardware type (axisHw) and the position encoder type (posEncoderType) parameters. The TNC control detects that the specified encoder connection method does not match the configured axis hardware interface.
HEIDENHAIN 230-01BF - Encoder type not permitted for axis
Encoder type not permitted for axis
This TNC7/TNC 640 error indicates an issue with 230-01BF. An impermissible combination of Axes->PhysicalAxes->CfgAxis->axisHw and Axes->ParameterSets->CfgAxis.
Root Cause Summary
HEIDENHAIN alarm 230-01BF occurs when there is an incompatible configuration between the axis hardware type (axisHw) and the position encoder type (posEncoderType) parameters. The TNC control detects that the specified encoder connection method does not match the configured axis hardware interface.
Safety
Causes and Fixes
Access axis configuration menu
Navigate to MOD function -> System Parameters -> Axes -> PhysicalAxes -> CfgAxis and note the axisHw setting for the affected axis.
Document current settings before making changes for rollback purposes
Check encoder type configuration
Go to Axes -> ParameterSets -> CfgAxisHardware -> posEncoderType and verify the encoder connection type matches the axisHw configuration.
Incorrect encoder configuration can cause axis runaway - ensure machine is in safe state
Correct configuration mismatch
Set posEncoderType to match axisHw: for CC422/CC424/CC520 use encoder connected to CC, for AnalogMC/DisplayMC/ManualMC use encoder connected to MC.
Use TNCremo for remote parameter editing to avoid machine downtime
Restart control and verify
Perform control restart and check that alarm 230-01BF clears, then test axis movement in manual mode.
Always perform reference point return after encoder configuration changes
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.