HEIDENHAIN 230-01C0 - Analog output of axis was assigned twice
Alarm 230-01C0 occurs when multiple axes are configured to use the same analog output channel in the machine parameters. This creates a conflict where two or more axes attempt to simultaneously control the same analog output, typically due to incorrect parameter assignments in MP720 or duplicate axis configurations.
HEIDENHAIN 230-01C0 - Analog output of axis was assigned twice
Analog output of axis was assigned twice
The analog output for this axis has been assigned to multiple axes simultaneously. When two or more axes attempt to use the same analog output channel at once, a conflict occurs that prevents proper operation.
Root Cause Summary
Alarm 230-01C0 occurs when multiple axes are configured to use the same analog output channel in the machine parameters. This creates a conflict where two or more axes attempt to simultaneously control the same analog output, typically due to incorrect parameter assignments in MP720 or duplicate axis configurations.
Safety
Causes and Fixes
Access machine parameters
Press MOD key, select 'Machine Parameters' from the operating mode menu, enter password if required.
Always backup current parameters before making changes using the data backup function.
Check MP720 assignments
Navigate to MP720 'Analog output for axis' and verify each axis has a unique analog output number assigned. Look for duplicate values across all configured axes.
Document current settings before making changes as incorrect assignments can cause servo instability.
Correct duplicate assignments
Assign unique analog output numbers to each axis in MP720, ensuring no two axes share the same output channel number.
Use sequential numbering starting from 0 for cleaner organization.
Restart control and test
Perform a control restart (Ctrl+Alt+Del) to activate new parameter settings, then test axis movement to verify proper operation.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.